Feedback system analysis
Check characteristic roots or assemble a signal-flow network from transfer blocks and inspect its response.
Method and interpretation
Rows are scaled by positive factors. Their first-column signs give the right-half-plane count. An all-zero row uses the derivative of its auxiliary polynomial. A zero leading entry uses a symbolic positive infinitesimal ε. For singular arrays, sign changes for p(s + ε) and p(s − ε) distinguish imaginary-axis roots. The polynomial GCD with its derivative detects repeated axis roots. Counts include multiplicity.
An asymptotically stable continuous-time characteristic polynomial has all roots in the open left half plane. Simple axis poles can support persistent oscillation, and an uncancelled transfer pole on the axis precludes BIBO stability. Stability of hidden states requires a realization. Input decimal arithmetic is exact within the displayed entry limits. Large table entries are abbreviated to six significant digits.
Michigan State University · Routh–Hurwitz examplesTransfer blocks
| Block | From | To | Numerator | Denominator |
|---|
Method, model export and limits
Define up to 32 summing nodes and 64 proper real rational blocks, each up to degree 15. Parallel branches, cycles, direct terms and self-loops are supported. Complex nodal and edge equations are solved simultaneously at DC and each selected angular frequency. This formulation can retain finite closed-loop DC gain around an integrator. Phase is wrapped to ±180°. A singular sampled frequency is identified individually, and a singular instantaneous algebraic loop blocks the calculation. Scaled pivots below 10⁻¹² trigger a conditioning warning.
A finite frequency sweep does not establish internal stability. The MATLAB script forms the full unreduced closed-loop state realization, reports internal poles and recomputes the response. Call verify_control_network(true) with Simulink installed to create a discrete model using exact zero-order-hold conversion at 480 samples/s or higher according to the pole and sweep frequencies. Call verify_control_network(false,true) to render a two-second unit-step video at 480 fps and verify its encoded playback rate. Rendering requires MATLAB graphics and Motion JPEG AVI support. Real-time execution speed depends on the host.